ESM-2H201 (Order no. 085620)
Choose content
Basic module ESM-2H.. ,Type IIIc evaluation unit for two-hand control
- Use up to category 4 according to EN ISO 13849-1
- Requirement level IIIC according to EN ISO 13851
- LED status indicators
- Operation by 2-hand control
- 2 redundant safety contacts
- Short circuit and earth fault/ground fault monitoring can be selected

Description
Relay outputs
The outputs are electrically decoupled and of redundant design.
Connection
- Two pushbuttons each with one NC contact and one NO contact that are monitored for simultaneity according to EN ISO 13851. In this way a high level of protection against tampering is provided.
- Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary
- Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Connection options
By using suitable wiring the following function can be selected:
- Monitoring of downstream relays or contactors.


Dimensional drawings

Connection examples

Technical data
Approvals


Operating and display elements
| LED display | 2 status displays (green) for relays K1 and K2 |
Electrical connection values
| Power consumption | |||||||||
| at 24 V DC | 1.5 W | ||||||||
| Connection cross section | 0.14 ... 2.5 mm² (Connection terminals (size)) | Outputs | |||||||
| |||||||||
| Rated insulation voltage Ui | 250 V | ||||||||
| Rated supply frequency | 50 ... 60 Hz | ||||||||
| Rated impulse voltage Uimp | 4 kV | ||||||||
| Operating voltage | |||||||||
| AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.) | ||||||||
| Test voltage | |||||||||
| Control voltage / contacts | 2.5 kV | ||||||||
| Control voltage | |||||||||
| on S12/S13 and S22/S23 | 24 V DC | ||||||||
| Control current | |||||||||
| both pushbuttons 2x | 40 mA | ||||||||
| Over voltage category | III | ||||||||
| Reverse polarity protection | |||||||||
| On version UB = 24 V DC | Yes | ||||||||
| Degree of contamination (external, according to EN 60947-1) | 2 | ||||||||
| Safety contacts 13/14, 23/24 | |||||||||
| Output type | Relay contacts, floating and positively driven (redundant) | ||||||||
| Cumulative current | max. 12 A for all contacts | ||||||||
| Synchronization time | max. 0.5 s | ||||||||
| Time delay | |||||||||
| After operation of the push buttons | max. 0.02 s Response delay time | ||||||||
Mechanical values and environment
| Connection type | Connection terminals |
| Storage temperature | -25 ... 70 °C |
| Control cable length | |
| with conductor cross-section 0.75 mm2 | 1000 m |
| Mechanical life | |
| operating cycles | 10 x 10⁶ |
| Mounting type | Mounting rail TH 35 (EN IEC 60715) |
| Degree of protection | IP20 |
| Ambient temperature | |
| at UB = 24 V AC | -15 ... 40 °C (60°C at 24 V DC) |
| Material | |
| Contact | AgSnO2 |
| Housing | Polyamide PA6.6 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Evaluating safety signals | PL e | - | 1.2x10-8 | 4 | 20 y |
| Only applies with switching voltage 24V DC and switching current up to 0.1 A (max. switching cycles 400,000 1/y) OR up to 1 A (max. switching cycles 100,000 1/y) OR up to 3 A (max. switching cycles 22,500 1/y) | |||||
Miscellaneous
| in compliance with | siehe Konformitätserklärung |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Download Complete Package (ZIP, 1,5 MB)
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2090791
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001502
Version
Language
Size
0,1 MB
Instructions
Operating instructions 2-Hand Safety Relay ESM-2H2..
Doc. no.
Version
Language
Size
Operating instructions 2-Hand Safety Relay ESM-2H2..
Doc. no.
2109071
Version
02/26
Language
Size
0,5 MB
Mode d’emploi Relais commande bimanuelle de sécurité ESM-2H2..
Doc. no.
2109071
Version
02/26
Language
Size
0,5 MB
Manual de instrucciones Relé de seguridad para mando bimanual ESM-2H2..
Doc. no.
2109071
Version
02/26
Language
Size
0,5 MB
Betriebsanleitung Sicherheits-2-Hand-Relais ESM-2H2..
Doc. no.
2109071
Version
02/26
Language
Size
0,6 MB
Other Documents
Approvals and certificates
CCC
Doc. no.
Version
Language
Size
CCC
Doc. no.
20001849
Version
Language
Size
0,0 MB
TÜV Rheinland_ESM-2Hx_Zertifikat_01_205_5081_03_26
Doc. no.
Version
Language
Size
TÜV Rheinland_ESM-2Hx_Zertifikat_01_205_5081_03_26
Doc. no.
20001848
Version
Language
Size
0,6 MB
WEEE
Doc. no.
Version
Language
Size
WEEE
Doc. no.
ECO20001806
Version
Language
Size
0,1 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
1,0 MB
c UL us
Doc. no.
Version
Language
Size
0,2 MB
Sales documents
Relais de Sécurité ESM
Doc. no.
Version
Language
Size
Relais de Sécurité ESM
Doc. no.
110652
Version
07-02/25
Language
Size
2,9 MB
Relé de seguridad ESM
Doc. no.
Version
Language
Size
Relé de seguridad ESM
Doc. no.
175349
Version
07-02/25
Language
Size
2,9 MB
Safety Relays ESM
Doc. no.
Version
Language
Size
Safety Relays ESM
Doc. no.
110651
Version
07-02/25
Language
Size
2,9 MB
Sicherheitsrelais ESM
Doc. no.
Version
Language
Size
Sicherheitsrelais ESM
Doc. no.
110650
Version
07-02/25
Language
Size
2,8 MB
ePlan macros
EUC.085620
Doc. no.
Version
Language
Size
EUC.085620
Doc. no.
Version
Language
Size
0,4 MB
Ordering data
| Ordernumber | 085620 |
| Item designation | ESM-2H201 |
| Gross weight | 0,213kg |
| Global Trade Item Number (GTIN) | 4047048006539 |
| Customs tariff number | 85364110 |
| ECLASS 11.0 | 27-37-18-19 Device for monitoring of safety-related circuits |
