CTS-C2-BR-CC-FLX-AP-VAB-169613/V20 (Sip. No. 178388)

CTS-C2-BR FlexFunction safety switch with guard locking, RFID, PVC connection cable with M12 plug connector(s), 20 switches per package

  • 20 CTS-C2-BR-CC-FLX-AP-VAB-169613 safety switches per packaging unit
CTS-C2-BR-CC-FLX-AP-VAB-169613/V20 (Sip. No. 178388)

Teknik Veriler

Switch CTS-C2-BR-CC-FLX-AP-VAB-169613 (Order no. 169613)

Switch CTS-C2-BR-CC-FLX-AP-VAB-169613  (Order no. 169613)

Electrical connection values

Fuse
IMP 1 ... 8 A external
UB 1 ... 8 A external
Power consumption 9 W
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 32 V
Rated impulse voltage Uimp 0.8 kV
Operating voltage DC
UB 24 V DC -15% ... +20% (reverse polarity protected, regulated, residual ripple<5%, SELV)
Discrepancy time max. 10 ms
Turn-on time max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Solenoid operating voltage DC 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load
according to UL DC 24 V, Class 2
Safety class III
Current consumption
IUB 50 mA
IIMP 500 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output Ox/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Output current 1 ... 10 mA
Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-4V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths)
Output current
per safety output FO1A / FO1B 1 ... 75 mA
Utilization category
DC-13 24V 75mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Test pulse duration max. 0.3 ms
Test pulse interval min. 96 ms

Mechanical values and environment

Anfahrgeschwindigkeit max. 20 m/min
Extraction force 25 N
Ready delay max. 5 s
Actuating force 25 N
Installation orientation any
Storage temperature -25 ... 70 °C
Mechanical life 1 x 10⁶
Retention force 10 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature -20 ... 50 °C
Material
Connecting cable PVC
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic
Locking force Fmax 5000 N
Locking force FZh 3800 N
Guard locking principle Open-circuit current principle
Connection X2
Connection type Connecting cable with plug connector M12
Static bending radius 8x cable diameter
Cable outlet straight
Cable length 0.25 m
Number of pins 5
Connection X1
Connection type Connecting cable with plug connector M12
Static bending radius 8x cable diameter
Cable outlet straight
Cable length 0.25 m
Number of pins 8
Safety outputs FO1A, FO1B
Switching frequency max. 0.2 Hz

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e36.44x10-9420 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Sipariş verileri

Sip. No. 178388
Makale adı CTS-C2-BR-CC-FLX-AP-VAB-169613/V20
Ağırlık 7,55kg
ECLASS 11.0 27-27-24-05 Safety-related transponder switch with guardlocking