CTS-C2-BR-CC-FLX-AP-VAB-169613/V20 (Rend. sz. 178388)
Válasszon tartalmat
CTS-C2-BR FlexFunction safety switch with guard locking, RFID, PVC connection cable with M12 plug connector(s), 20 switches per package
- 20 CTS-C2-BR-CC-FLX-AP-VAB-169613 safety switches per packaging unit

Műszaki adatok
Switch CTS-C2-BR-CC-FLX-AP-VAB-169613 (Order no. 169613)
Electrical connection values
| Fuse | |
| IMP | 1 ... 8 A external |
| UB | 1 ... 8 A external |
| Power consumption | 9 W |
| rated conditional short-circuit current | 100 A |
| Rated insulation voltage Ui | 32 V |
| Rated impulse voltage Uimp | 0.8 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +20% (reverse polarity protected, regulated, residual ripple<5%, SELV) |
| Discrepancy time | max. 10 ms |
| Turn-on time | max. 400 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Solenoid operating voltage DC | 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV |
| Solenoid duty cycle | 100 % |
| Risk time according to EN 60947-5-3 | max. 200 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
| Switching load | |
| according to UL | DC 24 V, Class 2 |
| Safety class | III |
| Current consumption | |
| IUB | 50 mA |
| IIMP | 500 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output Ox/C | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Output current | 1 ... 10 mA |
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| UFO1A /UFO1B HIGH | UB-4V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
| Output current | |
| per safety output FO1A / FO1B | 1 ... 75 mA |
| Utilization category | |
| DC-13 | 24V 75mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 96 ms |
Mechanical values and environment
| Anfahrgeschwindigkeit | max. 20 m/min |
| Extraction force | 25 N |
| Ready delay | max. 5 s |
| Actuating force | 25 N |
| Installation orientation | any |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 1 x 10⁶ |
| Retention force | 10 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | -20 ... 50 °C |
| Material | |
| Connecting cable | PVC |
| Switch head cover | Die-cast zinc |
| Safety switch housing | Reinforced thermoplastic |
| Locking force Fmax | 5000 N |
| Locking force FZh | 3800 N |
| Guard locking principle | Open-circuit current principle |
| Connection X2 | |
| Connection type | Connecting cable with plug connector M12 |
| Static bending radius | 8x cable diameter |
| Cable outlet | straight |
| Cable length | 0.25 m |
| Number of pins | 5 |
| Connection X1 | |
| Connection type | Connecting cable with plug connector M12 |
| Static bending radius | 8x cable diameter |
| Cable outlet | straight |
| Cable length | 0.25 m |
| Number of pins | 8 |
| Safety outputs FO1A, FO1B | |
| Switching frequency | max. 0.2 Hz |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Letöltések
Sales documents
One fits all - CTS Safety switch
Dok. sz.
Változat
Nyelv
Méret
One fits all - CTS Safety switch
Dok. sz.
169642
Változat
03-10/25
Nyelv
Méret
11,4 MB
One fits all - Interrupteur de sécurité CTS
Dok. sz.
Változat
Nyelv
Méret
One fits all - Interrupteur de sécurité CTS
Dok. sz.
169846
Változat
03-10/25
Nyelv
Méret
11,4 MB
Rendelési adatok
| Rend. sz. | 178388 |
| Cikk neve | CTS-C2-BR-CC-FLX-AP-VAB-169613/V20 |
| Súly | 7,55kg |
| ECLASS 11.0 | 27-27-24-05 Safety-related transponder switch with guardlocking |