ESM-BA201P (Sip. No. 097226)

Basic module ESM-BA2.., 2 safety contacts, cat. 4

  • ESM-BA.. Use up to category 4 according to EN ISO 13849-1
  • LED status indicators
  • 1-channel or 2-channel control
  • 2 redundant safety contacts
  • Short circuit and earth fault/ground fault monitoring
  • plug-in connection terminals
ESM-BA201P (Sip. No. 097226)

Açıklama

Relay outputs

The outputs are electrically decoupled and of redundant design.

Connection options

By using suitable wiring, the following functions can be selected:

  • Relay start with automatic start or a start button
  • Monitoring of downstream relays or contactors.
  • Simultaneity monitoring to monitor safety components over time
  • Relay start using a monitored start button
  • Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary
  • Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.

Important:

Depending on the device in question, a connection kit will be required.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
ESM-BA2...

Connection examples

Connection examples

Teknik Veriler

Approvals

c_UL_us_E155795_4/1CCC2024010305659956_ESM

Operating and display elements

LED display 2 status displays (green) for relays K1 and K2

Electrical connection values

Power consumption
at 24 V DC 1.5 W
Connection cross section 0.14 ... 2.5 mm² (Connection terminals (size))
Outputs
NumberTypeFunctionFootnote
2Relay contacts, floating and positively driven (redundant)Safety contacts 13/14, 23/24(Normally open contact)
Rated insulation voltage Ui 250 V
Rated supply frequency 50 ... 60 Hz
Rated impulse voltage Uimp 4 kV
Operating voltage
AC/DC 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.)
Test voltage
Control voltage / contacts 2.5 kV
Control voltage
to S11 DC 24 V
Control current
S11...S14 40 mA
Over voltage category III
Reverse polarity protection
On version UB = 24 V DC Yes
Degree of contamination (external, according to EN 60947-1) 2
Safety contacts 13/14, 23/24
Fuse
Contact fuses 10 AgG
Output type Relay contacts, floating and positively driven (redundant)
Utilization category
AC-12 6A resistive load, 250 V (6 operating cycles/min.)
DC-13 24 V 3A
AC-15 250 V 3A
DC-12 6A resistive load, 24 V (6 operating cycles/min.)
Switching voltage
AC max. 250 V
Switching current
at 5 V min. 10 mA

Mechanical values and environment

Connection type plug-in connection terminals
Storage temperature -25 ... 70 °C
Control cable length
with conductor cross-section 0.75 mm2 1000 m
Mechanical life
operating cycles 10 x 10⁶
Mounting type Mounting rail TH 35 (EN IEC 60715)
Degree of protection IP20
Ambient temperature
at UB = 24 V AC -15 ... 40 °C (+60 °C at 24 V DC and at 20% undervoltage, Tmax: 50 °C)
Material
Housing Polyamide PA6.6
Contact AgSnO2

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Evaluating safety signalsPL e-1.2x10-8420 y
Only applies with switching voltage 24V DC and switching current up to 0.1 A (max. switching cycles 400,000 1/y) OR up to 1 A (max. switching cycles 100,000 1/y) OR up to 3 A (max. switching cycles 22,500 1/y)


Miscellaneous

in compliance with siehe Konformitätserklärung

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 1,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 097226
Makale adı ESM-BA201P
Ağırlık 0,181kg
Gümrük sınıfı 85364110
ECLASS 11.0 27-37-18-19 Device for monitoring of safety-related circuits