Safety switch CTS-BP
Your Benefits
- safety switch with guard locking
- Safety category 4 and PL e according to EN ISO 13849-1
- FlexFunction device: Guard lock monitoring and coding level are configured via actuation.
function
Thanks to transponder technology, a single CTS already achieves category 4 / PL e according to EN ISO 13849-1 without additional fault exclusion and meets all requirements of EN ISO 14119. It is ideally suited for applications requiring compact switch dimensions and a high locking force of up to 5,000 N.
Versatile in Use
The CTS reliably secures safety doors and flaps on machines and systems. It is suitable for both process and personal protection. With three different mounting orientations and its compact design, the CTS offers flexible application options. Thanks to optional accessories, such as the retrofittable escape release, the CTS adapts to any application.The new LED concept with RGB LEDs enables diagnostics visible from three sides, providing detailed status information and error messages.
FlexFunction
The CTS safety switch is a FlexFunction device and thus combines various functions in a single unit. The selection of functions is determined by the choice of actuator. Consequently, the switch can be configured with or without guard locking monitoring and with high- or low-coded evaluation.Mounting and Operation
The CTS consists of two components: a safety switch and a separate actuator. During mounting, the safety switch is mounted on the fixed part of the guard, and the actuator is mounted on the moving part.The actuator is mounted on a floating bearing and is therefore tolerant of vibrations or offset. It is suitable for both swing and sliding doors and can also be used with small door radii.
Ürünler (15)
Sonuç bulunamadı
172870
CTS-C1-BP-CC-FLX-AP-USA-172870
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PUR with plug connector M12
CTS-C1-BP-CC-FLX-AP-USA-172870
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PUR with plug connector M12
- Closed-circuit current principle
- Guard locking (OL) and door position 1 (OD) monitoring outputs
- Connecting cable PUR, 25 cm, plug connector M12, 8-pin
172474
CTS-C1-BP-CC-FLX-AP-VBB-172474
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
CTS-C1-BP-CC-FLX-AP-VBB-172474
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
- Closed-circuit current principle
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- for connection to decentralized peripheral system
173730
CTS-C1-BP-CC-FLX-AP-VBB-173730
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
CTS-C1-BP-CC-FLX-AP-VBB-173730
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
- Closed-circuit current principle
- Door position 1 (OD) / guard locking (OL) monitoring outputs
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- for connection to decentralized peripheral system
176688
CTS-C1-BP-CC-FLX-AP-VBB-176688
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
CTS-C1-BP-CC-FLX-AP-VBB-176688
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
- Closed-circuit current principle
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- for direct connection to decentralized peripheral systems: ArmorBlock Guard I/O
178505
CTS-C1-BP-CC-FLX-AP-VBB-178505
CTS-C1-BP FlexFunction safety switch with guard locking, RFID, PVC connection cable with M12 plug connector(s), for connection to decentralized peripheral systems, stainless steel
CTS-C1-BP-CC-FLX-AP-VBB-178505
CTS-C1-BP FlexFunction safety switch with guard locking, RFID, PVC connection cable with M12 plug connector(s), for connection to decentralized peripheral systems, stainless steel
- Closed-circuit current principle
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- for connection to decentralized peripheral system
- Version with stainless-steel components
167917
CTS-C1-BP-CC-FLX-AP-VSA-167917
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BP-CC-FLX-AP-VSA-167917
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Guard locking (OL) and door position 1 (OD) monitoring outputs
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
169052
CTS-C1-BP-CC-FLX-AP-VSA-169052
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BP-CC-FLX-AP-VSA-169052
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Door position 1 (OD) / guard locking (OL) and escape release (OER) monitoring outputs
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
171593
CTS-C1-BP-CC-FLX-AP-VSA-171593
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BP-CC-FLX-AP-VSA-171593
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Guard locking (OL) and door position 2 (OT) monitoring outputs
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
176048
CTS-C1-BP-CC-FLX-AP-VSA-176048
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, PVC connection cable with M12 plug connector(s), Stainless Steel
CTS-C1-BP-CC-FLX-AP-VSA-176048
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, PVC connection cable with M12 plug connector(s), Stainless Steel
- Closed-circuit current principle
- Guard locking (OL) / door position 1 (OD) monitoring outputs
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
- Version with stainless-steel components
176974
CTS-C1-BP-CC-FLX-AP-VSA-176974
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BP-CC-FLX-AP-VSA-176974
Safety switch with guard locking CTS-C1-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Monitoring Output (OI) and Door Position 1 (OD)
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
174157
CTS-C2-BP-CC-FLX-AP-USA-174157
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PUR with plug connector M12
CTS-C2-BP-CC-FLX-AP-USA-174157
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PUR with plug connector M12
- Open-circuit current principle
- Guard locking for process protection
- Guard locking (OL) and door position 1 (OD) monitoring outputs
- Connecting cable PUR, 25 cm, plug connector M12, 8-pin
172475
CTS-C2-BP-CC-FLX-AP-VBB-172475
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
CTS-C2-BP-CC-FLX-AP-VBB-172475
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
- Open-circuit current principle
- Guard locking for process protection
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- for connection to decentralized peripheral system
173731
CTS-C2-BP-CC-FLX-AP-VBB-173731
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
CTS-C2-BP-CC-FLX-AP-VBB-173731
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
- Open-circuit current principle
- Guard locking for process protection
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- Door position 1 (OD) / guard locking (OL) monitoring output
- for connection to decentralized peripheral system
176689
CTS-C2-BP-CC-FLX-AP-VBB-176689
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
CTS-C2-BP-CC-FLX-AP-VBB-176689
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12, for connection to decentralized peripheral systems
- Open-circuit current principle
- Guard locking for process protection
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin
- for direct connection to decentralized peripheral systems: ArmorBlock Guard I/O
169051
CTS-C2-BP-CC-FLX-AP-VSA-169051
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C2-BP-CC-FLX-AP-VSA-169051
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connecting cable PVC with plug connector M12
- Open-circuit current principle
- Guard locking suitable for process protection only
- Guard locking (OL) and door position 1 (OD) monitoring outputs
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin