Safety switch with guard locking CTM-L2-BR, RFID, connection cable, connecting cable PVC, hygienic version
Open-circuit current principle
Guard locking for process protection
Multicode
Door position monitoring output/communication OD/C
Connection cable, connecting cable PVC, 15m, flying lead
Actuating/extraction/retention force: 35/30/15 N
Hygienic version
Description
Guard locking principle
Open-circuit current (power on to lock): On a guard with guard locking based on the open-circuit current principle, the guard is locked until the power supply to the guard locking solenoid is interrupted. Unlocking is by spring force. The term electrical guard locking is also used.
Guard locking for process protection
The safety switch meets the requirements for interlocking devices with guard locking for process protection. It does not possess safe guard lock monitoring.
Switching function
The safety outputs are switched on when guard locking is active.
Multicode evaluation
It is checked whether the actuator is of a type that can be detected by the system (multicode evaluation). The system possesses a low coding level. Every suitable actuator is detected by the switch.
Terminal assignment
Designation
Function
Connecting cable conductor coloring
FI1B
Enable input, channel B
WH
UB
Electronics and solenoid operating voltage, 24 V DC
BN
FO1A
Safety output, channel A
GN
FO1B
Safety output, channel B
YE
OD/C
Door position monitoring output/communication
GY
FI1A
Enable input, channel A
PK
0VUB
Electronics and solenoid operating voltage, 0 V DC
BU
IMP
Solenoid control input, 24 V DC
RD
Accessories required
Actuator is not included.
Dimension drawing
Wiring diagram
Dimensional drawings
1
LEDs
2
Active read head face
3
Auxiliary release (optional)
Connection examples
Technical data
Approvals
Workspace
Repeat accuracy R
10 %
Electrical connection values
Fuse
external (operating voltage UB)
0.7 ... 8 A
Power consumption
at max. switching frequency
3 W
Rated insulation voltage Ui
50 V
Rated impulse voltage Uimp
0.5 kV
Discrepancy time
both safety outputs
max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time
max. 500 ms
Solenoid duty cycle
100 %
Off-state current Ir
max. 0.25 mA
Risk time according to EN 60947-5-3
max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device
max. 10 ms
Switching load
DC 24V, UL Class 2 (alternatively, see operating instructions)
Safety class
III
Test pulse duration
max. 0.3 ms
Test pulse interval
100 ms
Degree of contamination (external, according to EN 60947-1)
3
Solenoid IMP
Input voltage
Guard locking active (closed)
20.4 ... 26.4 V DC
Guard locking not active (open)
0 ... 5 V DC
Current consumption
Guard locking active (closed)
20 ... 50 mA
Door position monitoring output/communication OD/C
Output type
p-switching, short circuit-proof
Output voltage
0.8xUB ... UB V DC
Switching current
1 ... 50 mA
Safety input
Current consumption
max. 7 mA Safety inputs Fl1A/Fl1B
Safety outputs FO1A/FO1B
Output type
2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B)
0 ... 1 V DC
HIGH U(FO1A) / U(FO1B)
UB-1.5 ... UB V DC
Discrepancy time
Acc. to EN IEC 60947-5-3
Utilization category
DC-13
24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Electrical switching frequency
max. 0.25 Hz
Switching current
per safety output FO1A / FO1B
1 ... 150 mA
Operating voltage UB
Operating voltage DC
UUB
24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Current consumption
IUB at operating voltage UB = 24 V
max. 500 mA
Mechanical values and environment
Anfahrgeschwindigkeit
max. 20 m/min
Connection type
Connecting cable (screwed tight, plug connector/mating component. Please observe the notes in the operating instructions when using high-pressure cleaners.)
Extraction force
30 N
Ready delay
5.5 s
Actuating force
35 N
Installation orientation
any
Switching frequency
max. 0.25 Hz
Storage temperature
-25 ... 70 °C
Mechanical life
1 x 10⁶
Overtravel
2 mm
Retention force
15 N
Shock and vibration resistance
Acc. to EN IEC 60947-5-3
Degree of protection
IP65/IP67/IP69/IP69K (In the inserted and screwed tight state)
Ambient temperature
at UB = 24 V DC
-20 ... 60 °C
Material
Cable sheath
PVC
Safety switch housing
Reinforced thermoplastic
Seals
Fluorinated rubber (FKM)
Encapsulation
Technomelt PA6208 black
Locking force Fmax
1300 N
Locking force FZh
1000 N
Guard locking principle
Open-circuit current principle
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL
Maximum SIL
PFHD
Category
Mission time
Monitoring of the guard position
PL e
3
4.11x10-9
4
20 y
Miscellaneous
Notices for UL approval
Operation only with UL Class 2 power supply or equivalent measures; see operating instructions