Safety switch CTS-BR
Your Benefits
- safety switch with guard locking
- Up to 20 safety switches can be connected in a series connection
- Safety category 4 and PL e according to EN ISO 13849-1
- FlexFunction device: Guard lock monitoring and coding level are configured via actuation.
function
Thanks to transponder technology, even a single CTS achieves category 4 / PL e according to EN ISO 13849-1 without additional fault exclusion and meets all requirements of EN ISO 14119. It is ideal for applications requiring compact switch dimensions and a high locking force of up to 3,900 N.
Versatile in Use
The CTS reliably secures safety doors and flaps on machines and systems. It is suitable for both process and personal protection. With three different mounting orientations and its compact design, the CTS offers flexible application options. Thanks to optional accessories, such as the retrofittable escape release, the CTS adapts to any application. ← The new LED concept with RGB LEDs enables diagnostics visible from three sides, providing detailed status information and error messages.FlexFunction
The CTS safety switch is a FlexFunction device and thus combines various functions in a single unit. The selection of functions is determined by the choice of actuator. Consequently, the switch can be configured with or without guard locking monitoring and with high- or low-coded evaluation.Installation and Operation
The CTS consists of two components: a safety switch and a separate actuator. During mounting, the safety switch is mounted on the fixed part of the guard, and the actuator is mounted on the moving part. ← The actuator is mounted on a floating bearing and is therefore tolerant of vibrations or offset. It is suitable for both swing and sliding doors and can also be used with small door radii.BR System Family
In theBR
version, up to 20 CTS-BR safety switches or other EUCHNER products belonging to the BR system family can be connected in series. There are two different wiring concepts:Series connection in the control cabinet:
Wiring is performed in the control cabinet. All information regarding the status of the individual CTS-BR units can be forwarded directly to the control system.
Series connection in the field:
For field wiring, EUCHNER offers the option of connecting multiple CTS-BRs to each other using M12 plugs and Y-splitters. A passive distribution module can also be used instead of the Y-plug connectors. With this device, all safety and status signals are collected in the field and transmitted to the control system via a single cable.
Termékek (8)
Nem található eredmény
173374
CTS-C1-BR-CC-FLX-AP-UAB-173374
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PUR with plug connector M12
CTS-C1-BR-CC-FLX-AP-UAB-173374
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PUR with plug connector M12
- Closed-circuit current principle
- Door position 1 (OD) and guard locking (OL) monitoring outputs
- Connecting cable PUR, 25 cm, 2 x plug connector M12, 5-pin and 8-pin
169053
CTS-C1-BR-CC-FLX-AP-V05-169053
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC
CTS-C1-BR-CC-FLX-AP-V05-169053
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC
- Closed-circuit current principle
- Guard locking (OL) and door position 1 (OD) monitoring outputs
- 2 x connecting cable PVC, 5 m, flying lead, 5-core and 8-core
169612
CTS-C1-BR-CC-FLX-AP-VAB-169612
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BR-CC-FLX-AP-VAB-169612
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Door position 1 (OD) and guard locking (OL) monitoring outputs
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin and 8-pin
174014
CTS-C1-BR-CC-FLX-AP-VSA-174014
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BR-CC-FLX-AP-VSA-174014
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
- Guard locking (OL) / door position 1 (OD) monitoring outputs
176452
CTS-C1-BR-CC-FLX-AP-VSA-176452
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C1-BR-CC-FLX-AP-VSA-176452
Safety switch with guard locking CTS-C1-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
- Closed-circuit current principle
- Suitable for connection to safety series connection GuardLinkTM
- Suitable for connection to the Flexi Loop safety series connection
- Guard locking (OL) / door position 1 (OD) monitoring outputs
- Connecting cable, PVC, 25 cm, plug connector M12, 8-pin
169613
CTS-C2-BR-CC-FLX-AP-VAB-169613
Safety switch with guard locking CTS-C2-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C2-BR-CC-FLX-AP-VAB-169613
Safety switch with guard locking CTS-C2-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
- Open-circuit current principle
- Guard locking for process protection
- Door position 1 (OD) and guard locking (OL) monitoring outputs
- Connecting cable PVC, 25 cm, 2 x plug connector M12, 5-pin and 8-pin
174018
CTS-C2-BR-CC-FLX-AP-VSA-174018
Safety switch with guard locking CTS-C2-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C2-BR-CC-FLX-AP-VSA-174018
Safety switch with guard locking CTS-C2-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
- Open-circuit current principle
- Guard locking for process protection
- Guard locking (OL) / door position 1 (OD) monitoring outputs
- Connecting cable PVC, 25 cm, plug connector M12, 8-pin
176453
CTS-C2-BR-CC-FLX-AP-VSA-176453
Safety switch with guard locking CTS-C2-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
CTS-C2-BR-CC-FLX-AP-VSA-176453
Safety switch with guard locking CTS-C2-BR FlexFunction, RFID, connecting cable PVC with plug connector M12
- Open-circuit current principle
- Guard locking for process protection
- Suitable for connection to safety series connection GuardLinkTM
- Suitable for connection to the Flexi Loop safety series connection
- Guard locking (OL) / door position 1 (OD) monitoring outputs
- Connecting cable, PVC, 25 cm, plug connector M12, 8-pin