MGB-L0B-PNA-L-124128 (Order no. 124128)
Interlocking module and bus module MGB-L0...-PN with 2 control elements, 7/8" and M12 plugs
- Interlocking (without guard locking)
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode

Description
Notice
This item is now available only as a replacement part. For new applications, we recommend the successor series, the MGB2.
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Emergency stop illuminated
Emergency stop with illumination that can be controlled as required.

Dimensional drawings

Technical data
Approvals



Workspace
| Secured switch-off distance sar | |
| Only for sliding door | 20 mm (Applies only to use on sliding doors with deactivated guard lock monitoring) |
Operating and display elements
| Occupancy diagram | |
| L0 | |
| B1 |
| Item | Color | Extras | Note slide-in label | Version | Switching element | Slide-in label | Number | Designation1 | LED |
|---|---|---|---|---|---|---|---|---|---|
| 90 | Illuminated pushbutton | 1NO | |||||||
| 93 | Emergency stop illuminated | 2 PD | |||||||
| 95 | Illuminated pushbutton | 1NO |
Electrical connection values
| Connecting cable | |
| Ethernet | Profinet I/O cable, at least cat. 5e |
| Rated insulation voltage Ui | 75 V |
| Rated impulse voltage Uimp | 0.5 kV |
| EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
| maximum feed-in current in the connection block | |
| X1, X2 | max. 4000 mA |
| Safety class | III |
| Current consumption | max. 500 mA |
| Transponder coding | Unicode |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Power supply X1 | |
| Fuse | |
| external | min. 1 A slow blow |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
| Power supply X2 | |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
| Connection type | |
| according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) |
| according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) |
| 7/8" Power (X1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| 7/8" Power (X2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| Installation orientation | Door hinge DIN left |
| Switching frequency | 0.25 Hz |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
| 1 x 10⁶ | |
| Response time | |
| Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP54 |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C |
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 4.07x10-8 | 4 | 20 y |
| Evaluating safety signals | PL e | 3 | 4.1x10-8 | 4 | 20 y |
| Applies to all additionally included safety functions such as emergency stop, enabling switch, etc. | |||||
| B10D | Mission time | |
|---|---|---|
| Emergency stop | 0.13x106 | 20 y |
Miscellaneous
| Slide-in label | |||||||
| |||||||
| Additional feature | incl. lens set, ID no. 120344 | ||||||
Interface
| Bus data protocol | Profinet (IEC 61158 type 10) |
| Safety data protocol | Profisafe (IEC 61784-3-3) |
| Date interface | Ethernet |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
Ordering data
| Ordernumber | 124128 |
| Item designation | MGB-L0B-PNA-L-124128 |
| Gross weight | 3,496kg |
| Global Trade Item Number (GTIN) | 4047048006430 |
| Customs tariff number | 85371098 |
| ECLASS 11.0 | 27-27-24-03 Safety-related transponder switch |