| Safety Switch with Semiconductor Output
For this switch in standard housing according to EN 60 947-5-2,
the read-head and evaluation device form a compact unit. The evaluation
unit in degree of protection IP 67 is fitted on site to the guard
device. Through the decentralized wiring concept when connecting
the plug connector, the wiring requirement is reduced to a minimum.
Electrically separate semiconductor outputs also permit operation
with switched-mode signals.
|

|
| Features |
- Two redundant semiconductor outputs (safety outputs)
with internally monitored contacts
- Safety switch in one housing according EN 60 947-5-2
- Short-circuit-proof signal and safety outputs
- High level of operating safety
- Read head and evaluation unit form a compact unit
- Reduction of wiring errors during commissioning
- Relocation of the evaluation unit from the control cabinet
to the guard
- Saves space in the control cabinet
- Available for safety level 3 and safety level 4 (according
to EN954)
|
Teach-in function of the evaluation unit
Prior to the system forming a functional unit, the actuator must
be allocated to the evaluation unit in a learn function. During
a learning process, the safety outputs and the door signal output
OUT are at LOW, i.e. the system is in a safe condition. Repeated
learning by the same actuator on the same evaluation unit is not
possible. The number of learning procedures on one evaluation
unit is limited to a maximum of 8. The evaluation unit can only
be operated with the last actuator learnt.
|
| Two redundant semiconductor outputs with internally
monitored contacts
Owing to dynamic scanning by the actuator and the diversity of
the safety electonics in conjunciton with two monitored safety
outputs, the evaluation unit enters the safe state when any detactable
error occurs. When the safety guard is opend, the safety outputs
disconnect the safety circuit and the door signal output (OUT)
is switched to LOW. The status of the safety outputs is monitored
internally by means of two microprocessors. If an internal error
occurs in the evaluation unit, the safety circuit is disconnected
and the red OUT/ERROR LED lights up.
|

(Enlarge)
|
| Large mechanical tolerances possible with door
alignment The characteristics of the Coded Electronic
Key Safety switches CES are the wide operating range of
the actuator as well as the integrated hysteresis. Therefore,
they are an excellent choice whenever machine doors are subject
to a high level of vibration or where repeatable positioning is
an issue.
|

(Enlarge)
|
|
|