ESM-BA301P (Order no. 097230)
Choose content
Basic module ESM-BA3.., 3 safety contacts, 1 auxiliary contact, cat. 4
- ESM-BA.. Use up to category 4 according to EN ISO 13849-1
- LED status indicators
- 1-channel or 2-channel control
- 3 redundant safety contacts
- 1 auxiliary contact (monitoring contact)
- Short circuit and earth fault/ground fault monitoring
- plug-in connection terminals

Description
Relay outputs
The outputs are electrically decoupled and of redundant design.
Connection options
By using suitable wiring, the following functions can be selected:
- Relay start with automatic start or a start button.
- Monitoring of downstream relays or contactors.
- Simultaneity monitoring to monitor safety components over time.
- Relay start using a monitored start button.
- Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary.
- Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Auxiliary contacts
The relays in the series ESM-BA3.. are available with electrically separate normally closed contacts and auxiliary contacts.
Important:
Depending on the device in question, a connection kit will be required.


Dimensional drawings

Connection examples

Technical data
Approvals


Operating and display elements
| LED display | 2 status displays (green) for relays K1 and K2 |
Electrical connection values
| Power consumption (apparent power) | |||||||||||||
| at 24 V AC | 4.5 VA | ||||||||||||
| Connection cross section | 0.14 ... 2.5 mm² (Connection terminals (size)) | Outputs | |||||||||||
| |||||||||||||
| Rated insulation voltage Ui | 250 V | ||||||||||||
| Rated supply frequency | 50 ... 60 Hz | ||||||||||||
| Rated impulse voltage Uimp | 4 kV | ||||||||||||
| Operating voltage | |||||||||||||
| AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.) | ||||||||||||
| Test voltage | |||||||||||||
| Control voltage / contacts | 2.5 kV | ||||||||||||
| Breaking capacity | |||||||||||||
| DC (for utilization category DC 13) | |||||||||||||
| Control voltage | |||||||||||||
| to S11 DC | 24 V | ||||||||||||
| Control current | |||||||||||||
| S11...S14 | 60 mA | ||||||||||||
| Over voltage category | III | ||||||||||||
| Reverse polarity protection | |||||||||||||
| On version UB = 24 V DC | Yes | ||||||||||||
| Degree of contamination (external, according to EN 60947-1) | 2 | ||||||||||||
| Safety contacts 13/14, 23/24, 33/34 | |||||||||||||
| Fuse | |||||||||||||
| Contact fuses | 10 AgG | ||||||||||||
| Output type | Relay contacts, floating and positively driven (redundant) | ||||||||||||
| Utilization category | |||||||||||||
| DC-12 | 8A resistive load, 40 V (6 operating cycles/min.) | ||||||||||||
| AC-12 | 8A resistive load, 250 V (6 operating cycles/min.) | ||||||||||||
| DC-13 | 24 V 3A | ||||||||||||
| AC-15 | 250 V 3A | ||||||||||||
| Switching voltage | |||||||||||||
| AC | max. 250 V | ||||||||||||
| Switching current | |||||||||||||
| at 5 V | min. 10 mA | ||||||||||||
| Cumulative current | max. 15 A for all contacts ("When several ESM-BA3.. units are closely spaced under load, the maximum cumulative current at an ambient temperature of T=20°C is 9 A; at T=30°C, 3 A; and at T=40°C, 1 A. If these currents are exceeded, a distance of 5 mm must be maintained between the devices.") | ||||||||||||
| Auxiliary Contacts 41/42 | |||||||||||||
| Output type | Relay contacts, dry contacts | ||||||||||||
Mechanical values and environment
| Connection type | Plug-in connection terminals |
| Storage temperature | -25 ... 70 °C |
| Control cable length | |
| with conductor cross-section 0.75 mm2 | 1000 m |
| Mechanical life | |
| operating cycles | 10 x 10⁶ |
| Mounting type | Mounting rail TH 35 (EN IEC 60715) |
| Degree of protection | IP20 |
| Ambient temperature | -15 ... 40 °C (If several ESM-BA3.. devices are closely spaced under load, the max. cumulative current is 9 A at an ambient temperature of T=20 °C , 3 A at T=30 °C and 1 A at T=40 °C. If these currents are exceeded, a spacing of 5mm between the devices must be observed.) |
| Material | |
| Contact | AgSnO2 |
| Housing | Polyamide PA6.6 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Evaluating safety signals | PL e | - | 1.2x10-8 | 4 | 20 y |
| Only applies with switching voltage 24V DC and switching current up to 0.1 A (max. switching cycles 500,000 1/y) OR up to 1 A (max. switching cycles 350,000 1/y) OR up to 2 A (max. switching cycles 100,000 1/y) | |||||
Miscellaneous
| in compliance with | siehe Konformitätserklärung |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Download Complete Package (ZIP, 1,7 MB)
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2090791
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001502
Version
Language
Size
0,1 MB
Instructions
Operating instructions Basic module ESM-BA3..
Doc. no.
Version
Language
Size
Operating instructions Basic module ESM-BA3..
Doc. no.
2090073
Version
09/25
Language
Size
0,5 MB
Mode d’emploi Module de base ESM-BA3..
Doc. no.
2090073
Version
09/25
Language
Size
0,5 MB
Manual de instrucciones Módulo básico ESM-BA3..
Doc. no.
2090073
Version
09/25
Language
Size
0,5 MB
Betriebsanleitung Basisgerät ESM-BA3..
Doc. no.
2090073
Version
09/25
Language
Size
0,5 MB
사용 설명서 기본 모듈 ESM-BA3..
Doc. no.
2090073
Version
09/25
Language
Size
0,8 MB
Other Documents
Application examples
Approvals and certificates
CCC
Doc. no.
Version
Language
Size
CCC
Doc. no.
20001849
Version
Language
Size
0,0 MB
TUEV Rheinland
Doc. no.
Version
Language
Size
TUEV Rheinland
Doc. no.
Version
Language
Size
0,6 MB
TÜV Rheinland
Doc. no.
Version
Language
Size
TÜV Rheinland
Doc. no.
20001714
Version
Language
Size
0,6 MB
WEEE
Doc. no.
Version
Language
Size
WEEE
Doc. no.
ECO20001806
Version
Language
Size
0,1 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
1,0 MB
Sales documents
Interrupteurs de sécurité à codage magnétique CMS
Doc. no.
Version
Language
Size
Interrupteurs de sécurité à codage magnétique CMS
Doc. no.
090606
Version
10-11/20
Language
Size
5,8 MB
Magnetically Coded Safety Switches CMS
Doc. no.
Version
Language
Size
Magnetically Coded Safety Switches CMS
Doc. no.
086824
Version
10-11/20
Language
Size
5,7 MB
Magnetisch codierte Sicherheitsschalter CMS
Doc. no.
Version
Language
Size
Magnetisch codierte Sicherheitsschalter CMS
Doc. no.
086823
Version
10-11/20
Language
Size
5,6 MB
Relais de Sécurité ESM
Doc. no.
Version
Language
Size
Relais de Sécurité ESM
Doc. no.
110652
Version
07-02/25
Language
Size
2,9 MB
Relé de seguridad ESM
Doc. no.
Version
Language
Size
Relé de seguridad ESM
Doc. no.
175349
Version
07-02/25
Language
Size
2,9 MB
Safety Relays ESM
Doc. no.
Version
Language
Size
Safety Relays ESM
Doc. no.
110651
Version
07-02/25
Language
Size
2,9 MB
Sicherheitsrelais ESM
Doc. no.
Version
Language
Size
Sicherheitsrelais ESM
Doc. no.
110650
Version
07-02/25
Language
Size
2,8 MB
ePlan macros
EUC.097230
Doc. no.
Version
Language
Size
EUC.097230
Doc. no.
Version
Language
Size
0,4 MB
Ordering data
| Ordernumber | 097230 |
| Item designation | ESM-BA301P |
| Gross weight | 0,175kg |
| Global Trade Item Number (GTIN) | 4047048006003 |
| Customs tariff number | 85364110 |
| ECLASS 11.0 | 27-37-18-19 Device for monitoring of safety-related circuits |